Navigate

Edit Dashboard

Analyze

1D Plots 2D Images Original Inputs Timing Output Warnings

1D Plots

2D Images

Table of Original Inputs

All inputs used for the calculation

Value
Target Mag 11.5
Saturation Level (electons) 154924.0
Instrument miri
Mode lrsslit
Aperture lrsslit
Disperser p750l
Subarray full
Readmode fast
Filter None
Primary/Secondary fp/f*

Timing Info

All the timing info needed for your observation. Overhead calculation assumes 30 minute target acquisition time.

Value
Transit Duration 0.915200
Seconds per Frame 2.775040
Time/Integration incl reset (sec) 27.750400
APT: Num Groups per Integration 9.000000
Num Integrations Out of Transit 1.000000
Num Integrations In Transit 119.000000
APT: Num Integrations per Occultation 120.000000
Observing Efficiency (%) 80.000000
Transit+Baseline, no overhead (hrs) 0.925013
Number of Transits 1.000000

Warnings

Pay attention to these warnings! If you do not see 'All good' written in each box, reconsider your run.

Value
Group Number Too Low? All good
Group Number Too High? All good
Non linear? All good
Saturated? All good
% full well high? All good
Num Groups Reset? All good

References

When publishing results based on PandExo, please cite:

Batalha, N.E., Mandell, A., Pontoppidan,K., et al., 2017, PASP, 129, 976

Download Data Download simulated observations with errors (text)