Navigate

Edit Dashboard

Analyze

1D Plots 2D Images Original Inputs Timing Output Warnings

1D Plots

2D Images

Table of Original Inputs

All inputs used for the calculation

Value
Target Mag 8.103
Saturation Level (electons) 52000.0
Instrument nirspec
Mode bots
Aperture s1600a1
Disperser g395h
Subarray sub2048
Readmode nrsrapid
Filter f290lp
Primary/Secondary rp^2/r*^2

Timing Info

All the timing info needed for your observation. Overhead calculation assumes 30 minute target acquisition time.

APT Inputs

Value
Instrument NIRSpec
Template NIRSpec Bright Object Time Series
Subarray SUB2048
Grating/Filter G395H/F290LP
Readout Pattern NRSRAPID
Groups per Integration 9
Exposures/Dith 1
Integrations/Exp 2600

Calculation Details

Value
Transit Duration (hr) 3.257000
Number of Transits 1
Transit + Baseline, No Overhead (hr) 6.514444
Observing Efficiency (%) 80
Frame Time (sec) 0.902000
Integrations In Transit 1300
Integrations Out of Transit 1300
Elapsed Time per Integration incl. Reset (sec) 9.020000
Science Time per Integration excl. Reset (sec) 7.216000

Warnings

Pay attention to these warnings! If you do not see 'All good' written in each box, reconsider your run.

Value
Group Number Too Low? All good
Group Number Too High? All good
Non linear? All good
Saturated? All good
% full well high? All good (76% < 80%)
Num Groups Reset? All good
Minimum Integrations? All good

References

When publishing results based on PandExo, please cite:

Batalha, N.E., Mandell, A., Pontoppidan,K., et al., 2017, PASP, 129, 976

Download Data Download simulated observations with errors (text)