Analyze

1D Plots 2D Images Original Inputs Timing Output Warnings

1D Plots

2D Images

Table of Original Inputs

All inputs used for the calculation

Value
Target Mag 11.354
Saturation Level (electons) 193655.0
Instrument miri
Mode lrsslitless
Aperture imager
Disperser p750l
Subarray slitlessprism
Readmode fast
Filter None
Primary/Secondary rp^2/r*^2

Timing Info

All the timing info needed for your observation. Overhead calculation assumes 30 minute target acquisition time.

Value
Transit Duration 1.04800
Seconds per Frame 0.15904
Time/Integration incl reset (sec) 3.33984
APT: Num Groups per Integration 20.00000
Num Integrations Out of Transit 754.00000
Num Integrations In Transit 1130.00000
APT: Num Integrations per Occultation 1884.00000
Observing Efficiency (%) 90.47619
Transit+Baseline, no overhead (hrs) 1.74785
Number of Transits 1.00000

Warnings

Pay attention to these warnings! If you do not see 'All good' written in each box, reconsider your run.

Value
Group Number Too Low? All good
Group Number Too High? All good
Non linear? All good
Saturated? All good
% full well high? % full well>80%
Num Groups Reset? All good

References

When publishing results based on PandExo, please cite:

Batalha, N.E., Mandell, A., Pontoppidan,K., et al., 2017, PASP, 129, 976

Download Data Download simulated observations with errors (text)